本文主要为广大网友提供“QSN750型直读光谱仪测定抗震钢筋中碳、硅、锰、磷、硫含量的不确定度评定”,希望对需要QSN750型直读光谱仪测定抗震钢筋中碳、硅、锰、磷、硫含量的不确定度评定网友有所帮助,学习一下!
转载请注明来源:毕业论文 需要其他论文可去论文范文查找。查看本站未公布的论文QSN750型直读光谱仪测定抗震钢筋中碳、硅、锰、磷、硫含量的不确定度评定(一)QSN750型直读光谱仪测定抗震钢筋中碳、硅、锰、磷、硫含量的不确定度评定
林春来 管金荣 郭淼 张莹
(国家建筑钢材质量监督检验中心 北京 100088)
摘要 依据JJF1059-1999相关技术规范,对QSN750型直读光谱仪测定抗震钢筋中碳、硅、锰、磷、硫含量的不确定度进行了评定和表述,分析了影响测量不确定度的各个因素,计算出各个分量并将其合成。
关键词 直读光谱仪;抗震钢筋;不确定度
Evaluation of uncertainty for determination of C,Si,Mn,P and S in aseismic ribbed bar by QSN 750 direct reading spectrometer
LinChun-lai GuanJin-rong Guomiao Zhangying
(China national construction steel quality supervision and test centre ,Beijing 100088 , China)
Abstract Based on the standard JJF1059-1999,the sources of the uncertainty by QSN 750 direct reading spectrometer for determination of C,Si,Mn,P and S in aseismic ribbed bar are analyzed,and the uncertainty of C,Si,Mn,P and S is evaluated and expressed. The value of uncertainty components in measurement is calculated and combined.
Keywords direct reading spectrometer; aseismic ribbed bar; uncertainty
据国家地震局测定,我国地震烈度在7度及以上地震区的面积达312万km2, 占全国总面积32.5%,而在6度以上的地震区则约占全国总面积60%。GB1499.2 - 2007 热轧带肋钢筋国家标准中增设了有较高性能要求的HRB400E和HRB500E 等抗震钢筋牌号。本文依据GB/T4336-2002对直读光谱法测定抗震钢筋中碳、硅、锰、磷、硫的不确定度进行评定。
1 实验部分
1.1 仪器和工作条件
QSN750型直读光谱仪(德国OBLF公司),光栅刻线数,2400条/毫米,一级谱线色散率为0.55nm/mm;Windows XP操作系统;氩气纯度:99.999%;入口压力:0.35 MPa。
1.2 标准样品、试样和样品制备
收稿日期:2010 -
作者简介:林春来(26岁) ,女,北京化工大学毕业,从事质量检验工作。
表1 标准样品:YSB S 11272-1997
元素 含量a(%) 标准偏差b(%)
C 0.249 0.005
Si 0.711 0.006
Mn 1.480 0.010
P 0.030 0.001
S 0.020 0.001
试样:HRB500E样品。
样品制备:依据GB/T4336-2002,标准样品和试样均使用磨样机制样,表面加工成光洁平面,将制备好的样品置于QSN750直读光谱仪激发台上进行检测。
1.3 检测方法
GB/T4336-2002 《碳素钢和中低合金钢火花源原子发射光谱分析方法(常规法)》QSN750型直读光谱仪测定抗震钢筋中碳、硅、锰、磷、硫含量的不确定度评定(一)......