摘 要
雷击引发的事故约占电力系统事故总量的一半,对系统的影响非常大,严重影响了供电的安全和可靠性,而避雷器是保证电力系统安全运行的重要保护设备之一,主要用于限制线路传来的雷电过电压或操作引起的内部过电压,目前变电所的避雷器基本上均采用金属氧化锌避雷器,金属氧化锌避雷器具有体积小、重量轻、功效好、安装方便等性能。变电所安装的避雷器在运行中绝大部分运行情况良好,但也会出现击穿或其它故障。
本文从金属氧化锌避雷器分类、特性、运行维护、常见故障分析以及维护试验等方面对金属氧化锌避雷器进行阐述,能够对现场工作起到一定的指导、借鉴作用。
关键词:氧化锌避雷器 运行监视 异常分析
论文类型:应用基础
Thesis: operation and maintenance of metal oxide surge arresters and application
ABSTRACT
Lightning strike caused the accident about half of the total power system accident, a very large impact on the system, a serious impact on the safety and reliability of power supply, while the arrester is one of the protective equipment to ensure the safe operation of power systems, mainly for limit line came the lightning over-voltage or the operation due to internal over-voltage substation arresters essentially metal oxide surge arresters, metal oxide surge arresters with small size, light weight, good efficacy, convenient installation performance. Substation installation of surge arresters in the operation of most of the operation, but also a breakdown or other failure. From the metal zinc oxide arrester classification, characteristics, operation and maintenance of common fault analysis and maintenance tests described aspects of the metal zinc oxide arrester, on-site work to play a guidance and reference.
Keywords: zinc oxide arrester operation monitoring anomaly analysis
Paper Type: application of basic
目 录
1 绪论 1
1.1 课题的背景与意义 1
1.2 本文主要工作介绍 1
2 氧化锌避雷器的分类和特性 3
2.1 氧化锌避雷器的分类 3
2.2 氧化锌避雷器特性 4
3 氧化锌避雷器的运行监视 7
3.1 运行巡视的意义 7
3.2 避雷器正常运行巡视项目 7
3.3 避雷器特殊巡视项目 7
3.4 巡视中存在的问题 8
3.5 加强避雷器巡视的方法 8
4 氧化锌避雷器的异常与处理 11
4.1 氧化锌避雷器常见异常 11
4.2 避雷器泄漏电流表 11
4.2.1 氧化锌避雷器泄漏电流表回路的工作原理 11
4.2.2 氧化锌避雷器泄漏电流表指示异常原因分析 12
5 氧化锌避雷器的维护与试验 13
5.1 氧化锌避雷器常用的测试方法 13
5.1.1 周期性预防性试验 13
5.1.2 带电测试 13
5.1.3 在线监测 13
5.1.4 红外热成像 13
5.2 避雷器附属设备的测试 13
5.3 金属氧化锌避雷器的试验项目、周期和要求(见表5-1) 13